Product Details:
Payment & Shipping Terms:
|
he K55 API 5CT casing or tubing is very similar to the J55 type. There is no difference in the chemical composition and yield strength, but the tensile strength of K55 is higher than J55 steel. In actual sales, the price of theses two materials is basically remained the same, and the purpose is very close. In the oil drilling, K55 API 5CT casing or tubing is a relatively common type. Because of its low grade steel, it is mainly used for shallow oil and gas extraction, especially in natural gas and coal bed methane exploitation. It is also most often used in shallow wells, geothermal wells, and water wells.
Specifications
1. Outer diameter
4 1/2", 5", 5 1/2", 6 5/8", 7", 7 5/8", 9 5/8", 10 3/4", 13 3/8", 16", 18 5/8", 20"
2. Wall thickness
5.21 - 16.13 mm
3. Thread type
SC(Short round thread), LC(Long round thread), BC(Buttress thread)
4. Length
R1(4.88-7.62m), R2(7.62-10.36m), R3(10.36-14.63m)
Chemical composition, mass fraction (%)
| Group | Grade | Type | C | Mn | Mo | Cr | Ni max. | Cu max. | P max. | S max. | Si max. | ||||
| min. | max. | min. | max. | min. | max. | min. | max. | ||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| 1 | H40 | - | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - |
| J55 | - | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - | |
| K55 | - | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - | |
| N80 | 1 | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - | |
| N80 | Q | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - | |
| R95 | - | - | 0.45 c | - | 1.9 | - | - | - | - | - | - | 0.03 | 0.03 | 0.45 | |
| 2 | M65 | - | - | - | - | - | - | - | - | - | - | - | 0.03 | 0.03 | - |
| L80 | 1 | - | 0.43 a | - | 1.9 | - | - | - | - | 0.25 | 0.35 | 0.03 | 0.03 | 0.45 | |
| L80 | 9Cr | - | 0.15 | 0.3 | 0.6 | 0.9 | 1.1 | 8 | 10 | 0.5 | 0.25 | 0.02 | 0.01 | 1 | |
| L80 | 13Cr | 0.15 | 0.22 | 0.25 | 1 | - | - | 12 | 14 | 0.5 | 0.25 | 0.02 | 0.01 | 1 | |
| C90 | 1 | - | 0.35 | - | 1.2 | 0.25 b | 0.85 | - | 1.5 | 0.99 | - | 0.02 | 0.01 | - | |
| T95 | 1 | - | 0.35 | - | 1.2 | 0.25 d | 0.85 | 0.4 | 1.5 | 0.99 | - | 0.02 | 0.01 | - | |
| C110 | - | - | 0.35 | - | 1.2 | 0.25 | 1 | 0.4 | 1.5 | 0.99 | - | 0.02 | 0.005 | - | |
| 3 | P110 | e | - | - | - | - | - | - | - | - | - | - | 0.030 e | 0.030 e | - |
| 4 | Q125 | 1 | - | 0.35 | 1.35 | - | 0.85 | - | 1.5 | 0.99 | - | 0.02 | 0.01 | - | |
| a The carbon content for L80 may be increased up to 0.50 % maximum if the product is oil-quenched. b The molybdenum content for Grade C90 Type 1 has no minimum tolerance if the wall thickness is less than 17.78 mm. c The carbon content for R95 may be increased up to 0.55 % maximum if the product is oil-quenched. d The molybdenum content for T95 Type 1 may be decreased to 0.15 % minimum if the wall thickness is less than 17.78 mm. e For EW Grade P110, the phosphorus content shall be 0.020 % maximum and the sulfur content 0.010 % maximum. NL = no limit. Elements shown shall be reported in product analysis. |
|||||||||||||||
Tensile and hardness requirements
| Group | Grade | Type | Total elongation under load % | Yield strength MPa | Tensile strength min. MPa | Hardness a max. | Specified wall thickness mm | Allowable hardness variation b HRC | ||
| min. | max . | HRC | HBW | |||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
| 1 | H40 | - | 0.5 | 276 | 552 | 414 | - | - | - | - |
| J55 | - | 0.5 | 379 | 552 | 517 | - | - | - | - | |
| K55 | - | 0.5 | 379 | 552 | 655 | - | - | - | - | |
| N80 | 1 | 0.5 | 552 | 758 | 689 | - | - | - | - | |
| N80 | Q | 0.5 | 552 | 758 | 689 | - | - | - | - | |
| R95 | - | 0.5 | 655 | 758 | 724 | - | - | - | - | |
| 2 | M65 | - | 0.5 | 448 | 586 | 586 | 22 | 235 | - | - |
| L80 | 1 | 0.5 | 552 | 655 | 655 | 23 | 241 | - | - | |
| L80 | 9Cr | 0.5 | 552 | 655 | 655 | 23 | 241 | - | - | |
| L80 | 13Cr | 0.5 | 552 | 655 | 655 | 23 | 241 | - | - | |
| C90 | 1 | 0.5 | 621 | 724 | 689 | 25.4 | 255 | ≤ 12.70 12.71 to 19.04 19.05 to 25.39 ≥ 25.40 | 3.0 4.0 5.0 6.0 | |
| T95 | 1 | 0.5 | 655 | 758 | 724 | 25.4 | 255 | ≤ 12.70 12.71 to 19.04 19.05 to 25.39 ≥ 25.40 | 3.0 4.0 5.0 6.0 | |
| C110 | - | 0.7 | 758 | 828 | 793 | 30 | 286 | ≤ 12.70 12.71 to 19.04 19.05 to 25.39. ≥ 25.40 | 3.0 4.0 5.0 6.0 | |
| 3 | P110 | - | 0.6 | 758 | 965 | 862 | - | - | - | - |
| 4 | Q125 | 1 | 0.65 | 862 | 1034 | 931 | b | - | ≤ 12.70 12.71 to 19.04 ≥ 19.05 | 3.0 4.0 5.0 |
| a In case of dispute, laboratory Rockwell C hardness testing shall be used as the referee method. b No hardness limits are specified, but the maximum variation is restricted as a manufacturing control in accordance with 7.8 and 7.9 of API Spec. 5CT. |
||||||||||